Skip to content

Large inverter (6,000 W+ running)

Westinghouse iGen12000DFc 12000 Peak Watt Dual Fuel Inverter Generator

A 9,000-running-watt dual fuel inverter with both a 14-50R and an L14-30R at 120/240 V — enough for the essentials tier of a whole house, fed through a transfer switch or interlock.

We earn a commission if you buy through links on this page, at no extra cost to you. It does not change what we recommend — see our affiliate disclosure. As an Amazon Associate I earn from qualifying purchases.

Best for

Home backup of the essentials — fridge, freezer, furnace blower, well or sump pump — through a transfer switch

Specifications

Output (gasoline)9,000 W running / 12,000 W peak
Output (propane)8,100 W running / 11,000 W peak
Voltage120/240 V; 37.5 A running at 240 V on gasoline
Outlets120/240 V 14-50R (50 A), 120/240 V L14-30R (30 A), 120 V 5-20R GFCI duplex
Transfer switchBoth 240 V outlets transfer-switch / interlock-kit ready (Westinghouse)
NeutralBonded
CO shutoffCO sensor — shuts the generator down if dangerous CO levels are detected nearby
ParallelWith 240 V Westinghouse inverter models (240 V parallel cables sold separately)
Run time19 hr at 25% load on 7.9 gal gasoline; 9 hr at 25% on a 20 lb propane tank
NoiseAs low as 64 dBA (distance not stated)
StartElectric, remote key fob, recoil
Weight189 lb dry, wheel kit included
EmissionsEPA compliant; not CARB compliant
Warranty3-year limited residential, 1-year commercial

Specifications as published by Westinghouse. Confirm against the current spec sheet before buying — manufacturers revise models without renaming them.

What's good

  • 9,000 running watts on gasoline covers the 5,000–7,500 W essentials tier with room for a window AC
  • Two 240 V outlets — a 14-50R and an L14-30R — so it fits either a 50 A or a 30 A inlet box
  • Still 8,100 running watts on propane, the fuel that stores for years without stabilizer
  • 7.9-gallon tank: Westinghouse rates it at 19 hours at quarter load

What's not

  • 189 lb — wheeled, but it lives where it runs
  • Ships with a bonded neutral: through an interlock kit or a transfer switch that doesn't switch the neutral that is a second neutral-ground bond, and the installer has to resolve it
  • Not CARB compliant — not a California option
  • Not a central-AC machine — a 2 to 2.5-ton compressor can surge 8,000–13,000 W on its own

Our verdict

This is the inverter that reaches the whole-house essentials tier: 9,000 running watts clears the 5,000–7,500 W a typical 1,500 sq ft home needs for its essentials, with headroom for a window AC and the clean output inverters are bought for. Both 240 V outlets mean it can feed a 30 A or a 50 A inlet, but have the electrician deal with the bonded neutral before the first outage. Run it outside, at least 20 feet from the house with the exhaust pointed away.

Compare with the alternatives

See the full inverter generators roundup →