Skip to content

Multi-sensor monitor (radon, PM2.5, CO2)

Airthings View Plus Radon & Air Quality Monitor

A seven-sensor indoor air quality monitor — radon, PM2.5, NDIR CO₂, VOCs, humidity, temperature and air pressure — with an e-paper display and Wi-Fi reporting to the Airthings app.

We earn a commission if you buy through links on this page, at no extra cost to you. It does not change what we recommend — see our affiliate disclosure. As an Amazon Associate I earn from qualifying purchases.

Best for

One monitor for cooking particulates, CO₂, humidity and radon together

Specifications

MeasuresRadon, PM2.5, CO₂, total VOCs, humidity, temperature, air pressure
CO₂ sensorNDIR, 400–5,000 ppm; ±50 ppm ±3% (50–95 °F, 0–80% RH, after ~7-day initial calibration)
PM2.5 sensorLaser-scattering optical particle counter, 0–1,000 µg/m³; ±(5 µg/m³ + 15%) below 150 µg/m³
RadonPassive diffusion chamber, alpha spectrometry, 0–500 pCi/L; ~10% after 7 days, ~5% after 2 months (at 5.4 pCi/L)
VOCsTotal VOCs in ppb (~7-day initial calibration)
SamplingEvery 5 minutes
Display2.9 in e-paper with red/yellow/green glow indicator
Power6 × AA (up to 2 years, depending on router and interval) or USB-C
Connectivity2.4 GHz Wi-Fi and Bluetooth LE; free Airthings app required for setup
Warranty1 year (North America); free 5-year extension when registered within 30 days

Specifications as published by Airthings. Confirm against the current spec sheet before buying — manufacturers revise models without renaming them.

What's good

  • Measures PM2.5 with a laser particle counter, so a seared steak or a wildfire-smoke day shows up as a real particulate number
  • NDIR CO₂ — measured, not estimated — alongside humidity in the same reading
  • Continuous radon monitoring, which no CO₂ monitor or hygrometer offers

What's not

  • Radon and CO₂ need days before the readings settle — Airthings quotes radon accuracy after 7 days and a ~7-day initial calibration for CO₂ and VOCs
  • The VOC figure is a total for a mix of chemicals, not a measurement of any specific one
  • Does not detect carbon monoxide or nitrogen dioxide — a gas range still needs a CO alarm, and the monitor is no substitute for one
  • Not for bathrooms: Airthings says spaces above 85% humidity can permanently damage the radon sensor

Our verdict

The pick when you want one device to answer several of our guides at once. It shows what the gas-stove and electrification guides describe — cooking makes PM2.5 on induction as well as gas — and whether the range hood is actually clearing it, while the NDIR CO₂ and humidity readings cover the stuffy-room questions. Radon is the reason to choose it over a CO₂-only monitor: it is independent of fuel choice and only shows up with days of continuous data, so treat the first week as warm-up and judge radon on the long-term average, not a single day's reading.

Compare with the alternatives

See the full air quality monitors roundup →