Furnace Size Calculator

Find what size furnace you need in BTU from your home's square footage, climate zone, and insulation — then see the difference between the heat your house needs (output BTU) and the rating on the box (input BTU). The result rounds to a real furnace size and shows why a high-efficiency replacement usually needs a smaller input rating than the unit it replaces.

ft²
ft

4550 BTU per ft² in this zone

Furnaces are sold by input BTU; what heats the house is output BTU = input × AFUE. This is a rule-of-thumb estimate — confirm with an ACCA Manual J load calculation before buying.

Furnace to shop for

100,000 BTU

input rating — delivers 95,000 BTU of heat at 95% AFUE

Heat your home needs (output)
95,000 BTU
Zone range for 2,000 ft²
90,000100,000
Input needed at 95% AFUE
100,000 BTU
Replacing an older 80% AFUE furnace with a condensing model? The new one usually needs a smaller input rating to deliver the same heat — set the AFUE above to see it.

A planning estimate from floor area and climate. Windows, insulation, air leakage, and your local design temperature move the real load far more than square footage — a contractor's Manual J is the final word.

Frequently asked questions

As a starting estimate, 60,000 to 120,000 BTU depending on your climate zone — roughly 60,000–80,000 BTU in the mild South, 80,000–100,000 BTU in the middle of the country, and 100,000–120,000 BTU in the cold North. The range is deliberately wide because square footage is the weakest of the inputs that set heating load. A Manual J calculation on a well-insulated 2,000 sq ft home often comes back far lower than the rule of thumb suggests.